House Profile

Project Team
Architecture & Passive House Design Architype Ltd. – architype.co.nz
Builder Carruthers Builders Ltd. – carruthersbuilds.com
Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz
Passive House Metrics
- Heating Demand15.35kWh/m2/year
- Heating Load10.86 W/m2
- TFA139m2
- Form Factor3.0
- Air leakage @ 50Pa0.4 ACH/hour
- PER demand37kWh/m2/year
Passive House Database – TBA
Construction Details Average Values
- U-value External Walls0.19 W/(m2K)(R5.31)
- Kingspan Kooltherm K7 insulation board, 90mm timber stud wall with R2.8 Pink Batts, 45mm service cavity with R1.3 Earthwool batts.
- U-value Floor0.10W/(m2K)(R10.34)
- Concrete slab on grade with 300mm EPS and 50mm XPS.
- U-value Roof 0.14W/(m2K)(R7.3)
- Timber skillion roof with two layers of R4.3 Pink Batts
- U-value Glass0.52 W/(m2K)(R1.93)
- High performance triple glazing
- U-Windows0.9 W/(m2K)(R1.1)
- ThermaDura DesignLine windows and NatureLine doors
- Ventilation Efficiency 91%
- Zehnder ComfoAir200