House Profile

Project Team
Architecture & Passive House Design Architype Ltd. – architype.co.nz
Builder Jamie Heaps
Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz
Passive House Metrics
- Heating Demand14.47kWh/m2/year
- Heating Load9.88 W/m2
- TFA197.0m2
- Form Factor2.9
- Air leakage @ 50Pa0.3 ACH/hour
- PER demand42.0kWh/m2/year
Passive House Database – TBA
Construction Details Average Values
- U-value External Walls0.21 W/(m2K)(R4.73)
- 140mm timber stud wall with R4.3 Pink Batts, Intello air control layer, varying depth insulated service cavity.
- U-value Floor0.30W/(m2K)(R3.30)
- Concrete slab with 200mm Expol ThermaSlab H
- U-value Roof 0.14W/(m2K)(R7.21)
- Warmseal PIR warm roof and timber I-joist roof with Pink Batt insulation, Intello air control layer and uninsulated service cavity.
- U-value Glass0.52 W/(m2K)(R1.91)
- 4:/18/4:/18/4 90% Ar
- U-Windows0.9 W/(m2K)(R1.1)
- Eco Windows ECO PVC83
- Ventilation Efficiency89%
- Zehnder ComfoAir Q350 HRV