Goetz Wunderbar Passive House Auckland

House Profile
You can read more about the Goetz Family’s building journey on their website: www.wunderbar-passive-house.org.
Project Team
Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz
Passive House Metrics
- Heating Demand13.0 kWh/m2/year
- Heating Load10.7 W/m2
- TFA163.1m2
- Form Factor3.87
- Air leakage @ 50Pa0.6 ACH/hour
- PER demand54.7kWh/m2/year
Passive House Database - TBA
Construction Details Average Values
- U-value External Walls0.31 W/(m2K)(R3.2)
- Insulated concrete formwork to lower levels, timber framed walls to upper level.
- U-value Floor0.18W/(m2K)(R5.5)
- Concrete slab on grade with EPS insulation
- U-value Roof 0.20W/(m2K)(R4.9)
- Timber skillion roof with batts
- U-value Glass0.52 W/(m2K)(R1.9)
- PlaniTherm XN
- U-Windows 1.2 W/(m2K)(R0.8)
- Gealan S9000 uPVC windows
- Ventilation Efficiency 79%
- Stiebel Eltron - LWZ 180