House Profile

Project Team
Architecture & Passive House Design Architype Ltd. – architype.co.nz
Builder John Creighton Builders – johncreightonbuilders.co.nz
Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz
Passive House Metrics
- Heating Demand19.3 kWh/m2/year
- Heating Load10.3 W/m2
- TFA308 m2
- Form Factor2.9
- Air leakage @ 50Pa0.31 ACH/hour
- PER demand42 kWh/m2/year
Passive House Database – TBA
Construction Details Average Values
- U-value External Walls0.21 W/(m2K)(R4.8)
- 140mm stud wall with R4.4 Knauf Wall batts, ply air control layer, 45mm service cavity with R1.3 Knauf batts.
- U-value Floor0.45W/(m2K)(R2.2)
- Concrete slab with hollow waffle pods and 50mm continuous layer of XPS beneath pods and ribs
- U-value Roof 0.11W/(m2K)(R9.1)
- Pitched roof with attic trusses insulated with two layers of R4.4 Knauf wall batts
- U-value Glass0.64 W/(m2K)(R1.6)
- Saint-Gobain 5:/14/5/14/:5 (Ar90)
- U-Windows1.0 W/(m2K)(R1.0)
- Neuffer Eco Plano
- Ventilation Efficiency87%
- Zehnder ComfoAir Q350 HRV