House Profile

Project Team
Architecture LDM Design
Passive House Design Passive Analytics – passiveanalytics.com.au
Builder Hazelwood Builders – hazelwoodhomes.com.au
Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz
Design – Mark Hazelwood
Window Supplier – Hygge windows
Passive House Metrics
- Heating Demand10.33 kWh/m2/year
- Heating Load9.6 W/m2
- Cooling Demand8.0 kWh/m2/year
- Cooling Load20.0 W/m2
- TFA156 m2
- Form Factor3.7
- Air leakage @ 50Pa0.4 ACH/hour
- PER demand46 kWh/m2/year
Passive House Database – TBA
Construction Details Average Values
- U-value External Walls0.28 W/(m2K)(R3.62)
- SmartSIPS 165mm Neopor panels
- U-value Floor0.20W/(m2K)(R4.93)
- SmartSIPS 310mm Neopor panels
- U-value Roof 0.14W/(m2K)(R7.30)
- SmartSIPS 210mm Neopor panels
- U-value Glass0.52 W/(m2K)(R1.93)
- EN2plus 6*/12Ar/6/12Ar/*6
- U-Windows0.9 W/(m2K)(R1.1)
- Hygge Optima, Elite 92 and ThermoHS
- Ventilation Efficiency74%
- Zehnder ComfoAir200