House Profile

Project Team

Architecture LDM Design
Passive House Design Passive Analyticspassiveanalytics.com.au
Builder Hazelwood Builders – hazelwoodhomes.com.au
Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz

Design – Mark Hazelwood
Window Supplier – Hygge windows

 

Passive House Metrics

  • Heating Demand10.33 kWh/m2/year
  • Heating Load9.6 W/m
  • Cooling Demand8.0 kWh/m2/year
  • Cooling Load20.0 W/m
  • TFA156 m2
  • Form Factor3.7
  • Air leakage @ 50Pa0.4 ACH/hour
  • PER demand46 kWh/m2/year

Passive House Database – TBA

Construction Details Average Values

  • U-value External Walls0.28 W/(m2K)(R3.62)
  • SmartSIPS 165mm Neopor panels
  • U-value Floor0.20W/(m2K)(R4.93)
  • SmartSIPS 310mm Neopor panels
  • U-value Roof 0.14W/(m2K)(R7.30)
  • SmartSIPS 210mm Neopor panels
  • U-value Glass0.52 W/(m2K)(R1.93)
  • EN2plus 6*/12Ar/6/12Ar/*6
  • U-Windows0.9 W/(m2K)(R1.1)
  • Hygge Optima, Elite 92 and ThermoHS
  • Ventilation Efficiency74%
  • Zehnder ComfoAir200