Amaroo Mount Beauty

House Profile
Project Team
Architecture Eco:Logical Building Design - ecologicalbuildingdesign.com.au
Passive House Design Vital Aspect Paul Gray - vitalaspect.au
Structural Engineer Kusch - kusch.com.au
Builder Vital Aspect Rob Vandenberg - vitalaspect.au
Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz
Passive House Metrics
- Heating Demand10.5 kWh/m2/year
- Heating Load11.8 W/m2
- TFA170.2m2
- Form Factor3.2
- Air leakage @ 50Pa0.1 ACH/hour
- PER demand40.3kWh/m2/year
Passive House Database - TBA
Construction Details Average Values
- U-value External Walls0.27 W/(m2K)(R3.77)
- 140mm timber framed wall with R4.0 Bradford Gold batts, airtight membrane, 45mm uninsulated service cavity.
- U-value Floor0.40W/(m2K)(R2.48)
- Concrete slab with 75mm XPS R2.3 underslab insulation
- U-value Roof 0.11W/(m2K)(R8.82)
- 290mm R7.0 Bradford Gold ceiling batts +70mm R2.0 Soundscreen batts between hyjoists, airtight membrane
- U-value Glass0.58 W/(m2K)(R1.72)
- PressGlass Silverstar 4*/16Ar/4/16Ar/*4
- U-Windows1.0 W/(m2K)(R1.0)
- LogikWin 68
- Ventilation Efficiency87%
- Zehnder ComfoAir Q350