Clulow House Wanaka
House Profile
Project Team
Architecture Tony Mcmurray Architectural Design
Passive House Design VIA architecture Ltd - via-architecture.net
Builder Davidson Building Ltd
Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz
Passive House Metrics
- Heating Demand27.9 kWh/m2/year
- Heating Load16.3 W/m2
- TFA170.9m2
- Form Factor3.9
- Air leakage @ 50Pa0.9 ACH/hour
- PER demand48.9kWh/m2/year
Passive House Database - TBA
Construction Details Average Values
- U-value External Walls 0.21 W/(m2K)(R4.84)
- 140mm framing with 45mm services cavity
- U-value Floor0.11W/(m2K)(R8.79)
- MaxRaft slab
- U-value Roof 0.10W/(m2K)(R9.60)
- 300 HyJoist skillion roof with 90mm services cavity / Trussed roof with 90mm insulation in services cavity
- U-value Glass0.52 W/(m2K)(R1.92)
- Silverstar EN2plus (4:/20/4/20/:4)
- U-Windows0.9 W/(m2K)(R1.1)
- Thermadura DesignLine
- Ventilation Efficiency 81%
- Stiebel Eltron GmbH & Co. KG - LWZ 280 (Balance)