Meadowstone Passive House Wanaka
House Profile
Project Team
Architecture & Passive House Design Hiberna Ltd - hiberna.co.nz
Builder MA Building - mabuilding.co.nz
Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz
Passive House Metrics
- Heating Demand13.4 kWh/m2/year
- Heating Load13.2 W/m2
- TFA141.6m2
- Form Factor4.5
- Air leakage @ 50Pa0.3 ACH/hour
- PER demand35.4kWh/m2/year
Passive House Database - TBA
Construction Details Average Values
- U-value External Walls0.18 W/(m2K)(R5.55)
- 190mm timber framed wall with two layers of TerraLana R2.4 batts, Intello air control layer, 45mm service cavity with TerraLana R1.2 batts.
- U-value Floor0.11W/(m2K)(R8.80)
- Reinforced concrete slab on 300mm VH grade EPS.
- U-value Roof 0.10W/(m2K)(R10.46)
- Skillion roof with parallel chord trusses and two layers of TerraLana R4 batts, 7mm ply air control layer and 90mm service cavity with TerraLana R2.4 batts.
- U-value Glass0.55 W/(m2K)(R1.82)
- Imported high-performance triple glazing
- U-Windows1.0 W/(m2K)(R1.0)
- Bayerwald aluminium clad timber windows, HST HA97
- Ventilation Efficiency80%
- Stiebel Eltron LWZ280