Project Team
Architecture & Passive House Design Sang Architects – sangarchitects.com
Builder iCreate Building and Renovations Ltd
Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz
Passive House Metrics
- Heating Demand9.0 kWh/m2/year
- Heating Load7.2 W/m2
- TFA196 m2
- Form Factor3.3
- Air leakage @ 50Pa0.5 ACH/hour
- PER demand49 kWh/m2/year
Passive House Database – TBA
Construction Details Average Values
- U-value External Walls0.23 W/(m2K)(R4.37)
- ICF to lower level, SIPs and 20mm uninsulated services cavity to upper levels
- U-value Floor0.70 W/(m2K)(R1.43)
- Concrete slab on 200mm EPS
- U-value Roof 0.15 W/(m2K)(R6.73)
- SIPs, rondo ceiling
- U-value Glass0.57 W/(m2K)(R1.75)
- Eco Windows triple glazing
- U-Windows0.9 W/(m2K)(R1.1)
- Eco Windows Spruce, alu clad
- Ventilation Efficiency86%
- Zehnder Q450