House Profile

Project Team
Architecture & Passive House Design Maguire and Harford Architects Ltd – mah.co.nz
Builder Avenue Architectural Builders (Ben Calvin)
Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz
Passive House Metrics
- Heating Demand12.2 kWh/m2/year
- Heating Load8.2 W/m2
- TFA 188 m2
- Form Factor2.6
- Air leakage @ 50Pa0.3 ACH/hour
- PER demand43.0 kWh/m2/year
Passive House Database – TBA
Construction Details Average Values
- U-value External Walls0.20 W/(m2K)(R5.03)
- 7mm plywood bracing / 200mm LVL insulated LVL framing / intello / 45mm service cavity / gypsum board
- U-value Floor0.15W/(m2K)(R6.89)
- 7mm Plywood / Insulated 90mm Timber / Insulated 200mm Hyjoist / 19mm Plyoowd / 13mm Timber flooring
- U-value Roof 0.11W/(m2K)(R9.06)
- Roofing / Cavity / Underlay / 15mm Plywood / 240mm insulation / 90mm insulated service cavity / plasterboard
- U-value Glass0.52 W/(m2K)(R1.93)
- Stake Triple Glaze (Saint-Gobain) Planiclear 4mm/20mm/Planiclear Ultra NII 4mm/20mm/Planiclear Ultra NII 4mm
- U-Windows0.9 W/(m2K)(R1.1)
- Thermadura DesignLine – PASSIVE
- Ventilation Efficiency83%
- ComfoAir Q350 HRV