Te Whare Kuia Dunedin

House Profile
Project Team
Architecture & Passive House Design Architype Ltd. - architype.co.nz
Builder Wilson Builders - wilsonbuilders.nz
Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz
Passive House Metrics
- Heating Demand14.5 kWh/m2/year
- Heating Load9.8 W/m2
- TFA117.4m2
- Form Factor3.9
- Air leakage @ 50Pa0.3 ACH/hour
- PER demand45.0kWh/m2/year
Passive House Database - TBA
Construction Details Average Values
- U-value External Walls 0.16 W/(m2K)(R6.25)
- 142mm Kingspan SIP walls lined with Kingspan K17 insulated plasterboard
- U-value Floor0.12W/(m2K)(R8.55)
- Concrete slab with 300mm Expol Thermaslab
- U-value Roof 0.08W/(m2K)(R12.27)
- Timber truss roof and timber skillion roof with Knauf batts
- U-value Glass0.55 W/(m2K)(R1.82)
- PlaniTherm XN high performance triple glazing
- U-Windows0.9 W/(m2K)(R1.2)
- Gealan S9000 uPVC frames
- Ventilation Efficiency 87%
- Zehnder ComfoAir Q350