The Green House Auckland
Project Team
Architecture & Passive House Design Respond Architects - respondarchitects.co.nz
Builder Linmar Homes - linmarhomes.co.nz
Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz
Passive House Metrics
- Heating Demand13.3 kWh/m2/year
- Heating Load9.5 W/m2
- TFA217.1m2
- Form Factor2.7
- Air leakage @ 50Pa0.3 ACH/hour
- PER demand37.2kWh/m2/year
Passive House Database - TBA
Construction Details Average Values
- U-value External Walls0.31 W/(m2K)(R3.28)
- 115mm Formance SIPS with a 45mm service cavity insulated with Knauf R1.3 batts
- U-value Floor0.44W/(m2K)(R2.26)
- 220 waffle pod slab on 50mm continuous EPS insulation
- U-value Roof 0.19W/(m2K)(R5.27)
- 215mm Formance SIPS with a 45mm service cavity insulated with Knauf R1.3 batts
- U-value Glass1.33 W/(m2K)(R0.75)
- Lightbridge high performance triple glazing
- U-Windows1.4 W/(m2K)(R0.7)
- Starke 70 uPVC windows and Optimal timber front door
- Ventilation Efficiency84%
- Zehnder ComfoAir Q450 HRV