Passive House Metrics
- Heating Demand14.1 kWh/m2/year
- Heating Load12.6 W/m2
- TFA100 m2
- Form Factor3.5
- Air leakage @ 50Pa0.24 ACH/hour
- PER demand56 kWh/m2/year
Passive House Database – TBA
Construction Details Average Values
- U-value External Walls0.21 W/(m2K)(R4.7)
- Ply rigid air barrier, 140mm timber framing with R3 TerraLana batts, Intello air control layer, 70mm service cavity with R1.8 TerraLana batts, OSB wall lining.
- U-value Floor0.16W/(m2K)(R6.2)
- Suspended timber floor with OSB air control layer, I-joist flooring with R6.2 TerraLana batts and ply wind protection layer.
- U-value Roof 0.15W/(m2K)(R6.7)
- 240mm I-joists with R6.2 TerraLana batts, Intello air control layer, 45mm service cavity with R1.2 TerraLana batts, OSB lining.
- U-value Glass0.53 W/(m2K)(R1.9)
- Saint-Gobian 4XN-18 ar-4-18ar-4XN
- U-Windows1.0 W/(m2K)(R1.0)
- EcoWindows WoodALU
- Ventilation Efficiency83%