Walklin Residence New Plymouth
House Profile
Project Team
Architecture & Passive House Design eHaus - ehaus.co.nz
Builder eHaus - ehaus.co.nz
Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz
Passive House Metrics
- Heating Demand13.8kWh/m2/year
- Heating Load10.0W/m2
- Frequency of Overheating0.3%
- TFA216.7m2
- Form Factor3.4
- Air leakage @ 50Pa0.6ACH/hour
- PER demand35.4kWh/m2/year
Passive House Database - 6876
Construction Details Average Values
- U-value External Walls 0.24 W/(m2K)(R4.2)
- 140mm Insulated Timber Framed wall with 45mm insulated service cavity
- U-value Floor0.18W/(m2K)(R5.5)
- 100mm concrete slab with 200mm continuous EPS underneath
- U-value Roof 0.13W/(m2K)(R7.8)
- Flat (480mm insulation) and skillion roof (330mm insulation)
- U-value Glass1.12 W/(m2K)(R0.9)
- Planitherm XN (4:/16/4)
- U-Windows1.4 W/(m2K)(R0.7)
- Dopfner Premium IV68
- Ventilation Efficiency 85%
- Zehnder - ComfoAir Q450 HRV