Wildweed Farm Catterick WA
House Profile
Project Team
Architecture & Passive House Design Roger Joyner - Passivhaus Perth - passivhausperth.com.au
Builder J & K Reed Construction - jkrc.com.au
Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz
Passive House Metrics
- Heating Demand14.0 kWh/m2/year
- Heating Load9.6 W/m2
- TFA202.3m2
- Form Factor3.4
- Air leakage @ 50Pa0.3 ACH/hour
- PER demand42.3kWh/m2/year
Passive House Database - TBA
Construction Details Average Values
- U-value External Walls0.21 W/(m2K)(R4.72)
- 90mm timber framed wall with R2.2 Bradford Gold batts and 100mm Masterwall EPS external insulation with a rendered finish
- U-value Floor0.51W/(m2K)(R1.96)
- 100mm thick concrete slab on ground with 50mm XPS insulation beneath.
- U-value Roof 0.13W/(m2K)(R7.7)
- 200mm thick Bondor SolarSpan roof panels with 90mm service cavity insulated with R2.2 Bradford Gold wall batts
- U-value Glass0.48 W/(m2K)(R0.7)
- Optilite - 5Cl/18 90%Ar/5Comfort
- U-Windows1.7 W/(m2K)(R0.6)
- Double glazed white uPVC frames (Kommerling C70)
- Ventilation Efficiency77%
- ComfoAir Q350 HRV