Model 3

Project Team
Architecture & Passive House Design VIA architecture Ltd - via-architecture.net
Builder Basin Builders
Project Director Richard Pope
Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz
Passive House Metrics
- Heating Demand15.47kWh/m2/year
- Heating Load11.28 W/m2
- TFA217.4m2
- Form Factor3.4
- Air leakage @ 50Pa0.4 ACH/hour
- PER demand34kWh/m2/year
Passive House Database - TBA
Construction Details Average Values
- U-value External Walls0.13 W/(m2K)(R7.97)
- Prefabricated timber framed wall panels with exterior wood fibre board and insulated services cavity ICF (insulated concrete form) walls
- U-value Floor0.10W/(m2K)(R10.15)
- Concrete on EPS on ground, Suspended concrete on EPS
- U-value Roof 0.14W/(m2K)(R7.31)
- Prefabricated timber framed roof panels, part with insulated services cavity
- U-value Glass0.52 W/(m2K)(R1.92)
- Triple glazing with low-e and argon
- U-Windows0.8 W/(m2K)(R1.2)
- Thermadura Designline
- Ventilation Efficiency 87%
- Zehnder ComfoAir Q350 HRV, Comfort Vent Q350 HRV