Hamilton Kaminski House Tarras
House Profile
Project Team
Architecture & Passive House Design Rafe Maclean Architects - rafemaclean.co.nz
Structural Engineer BMC
Builder Dunlop Builders Ltd - dunlopbuilders.co.nz
Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz
Passive House Metrics
- Heating Demand15.2kWh/m2/year
- Heating Load12.7 W/m2
- TFA246.3m2
- Form Factor3.7
- Air leakage @ 50Pa0.4 ACH/hour
- PER demand27.6kWh/m2/year
Passive House Database - TBA
Construction Details Average Values
- U-value External Walls 0.19 W/(m2K)(R5.3)
- 190mm timber framed wall, insulated with Terra Lana insulation, Intello air control layer and insulated service cavity of varying size
- U-value Floor0.16W/(m2K)(R6.34)
- Concrete slab with 100mm EPS insulation beneath and 90mm XPS on top
- U-value Roof 0.13W/(m2K)(R7.67)
- Timber skillion roof with 300mm Terra Lana batts, Intello air control layer, and partially insulated service cavity
- U-value Glass0.54 W/(m2K)(R1.85)
- Metro Low E Triple Glazing
- U-Windows0.8 W/(m2K)(R1.2)
- ThermaDura aluminium clad timber curtain wall
- Ventilation Efficiency 82%
- Zehnder ComfoAir Q450 HRV