Dawkins Victoria
House Profile
Project Team
Architecture Eco:Logical Building Design - ecologicalbuildingdesign.com.au
Passive House Design Detail Green - detailgreen.com.au
BuilderOvens and King Builders Pty Ltd. - wangarattabuilders.com.au
Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz
Passive House Metrics
- Heating Demand14.1 kWh/m2/year
- Heating Load13.5 W/m2
- TFA177.6m2
- Form Factor4.2
- Air leakage @ 50Pa0.5 ACH/hour
- PER demand30.9kWh/m2/year
Passive House Database - TBA
Construction Details Average Values
- U-value External Walls 0.26 W/(m2K)(R3.9)
- 140mm stud walls with fibreglass bats and a mix of service cavities and hempcrete on the interior.
- U-value Floor0.22W/(m2K)(R4.47)
- Waffle pod slab with 100mm XPS beneath
- U-value Roof 0.13W/(m2K)(R7.79)
- Timber truss roof with service cavity and fibreglass batt insulation
- U-value Glass0.55 W/(m2K)(R1.82)
- PressGlass Silverstar 4*/16Ar/4/16Ar/*4
- U-Windows1.1 W/(m2K)(R0.9)
- Logikhaus Aluclad timber 68 Oak
- Ventilation Efficiency 88%
- Zehnder ComfoAir Q350