Kanuka House Dunedin
House Profile
Project Team
Architecture & Passive House Design Architype Ltd. - architype.co.nz
Builder WD Homes - wdhomes.co.nz
Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz
Passive House Metrics
- Heating Demand14.5 kWh/m2/year
- Heating Load10.0 W/m2
- TFA124.6m2
- Form Factor3.3
- Air leakage @ 50Pa0.2 ACH/hour
- PER demand53.1kWh/m2/year
Passive House Database - TBA
Construction Details Average Values
- U-value External Walls0.22 W/(m2K)(R4.53)
- 140mm insulated timber framed wall with a 90mm insulated service cavity
- U-value Floor0.16W/(m2K)(R6.42)
- 100mm Concrete slab with 220mm continuous VH grade EPS
- U-value Roof 0.11W/(m2K)(R9.22)
- Truss roof with 320mm of glassfibre insulation
- U-value Glass0.52 W/(m2K)(R1.9)
- Thermadura Climaguard (4:/20/4/20/:4)
- U-Windows0.8 W/(m2K)(R1.3)
- DesignLine90 Passive
- Ventilation Efficiency 87%
- ComfoAir Q350 - Standard Heat Exchanger