Midway House Dunedin
House Profile
Project Team
Architecture & Passive House Design Architype Ltd. - architype.co.nz
Builder WD Homes - wdhomes.co.nz/
Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz
Passive House Metrics
- Heating Demand14.8 kWh/m2/year
- Heating Load10.4 W/m2
- TFA158.2m2
- Form Factor3.4
- Air leakage @ 50Pa0.3 ACH/hour
- PER demand40.4kWh/m2/year
Passive House Database -TBA
Construction Details Average Values
- U-value External Walls0.22 W/(m2K)(R5.04)
- Kingspan TEK SIP (142mm) plus 45mm service cavity
- U-value Floor0.17W/(m2K)(R5.78)
- concrete slab on grade with 200mm EPS insulation underneath, 50mm XPS edge and footing/thickening insulation
- U-value Roof 0.14W/(m2K)(R6.95)
- Timber truss and skillion roof with pink batts fibreglass insulation and Intello air control layer
- U-value Glass0.58 W/(m2K)(R1.74)
- Silverstar EN2plus (8:/14/8/14/:8 90% Ar) mixture (4:/20/4/20/:4 90% Ar)
- U-Windows0.9 W/(m2K)(R1.1)
- Thermadura Designline 90 Passive Timber/Alu windows
- Ventilation Efficiency 87%
- Zehnder Group Nederland B.V. - ComfoAir Q350 HRV, Comfort Vent Q350 HRV