Whittle House Matakohe
House Profile
Project Team
Architecture Sang Architects - sangarchitects.com
Passive House Design Sustainable Architecture Ltd - sustainablearchitecture.co.nz
Builder Bruyere Limited - bruyerepassivehomes.nz
Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz
Passive House Metrics
- Heating Demand12.3 kWh/m2/year
- Heating Load9.5 W/m2
- TFA151.9m2
- Form Factor3.5
- Air leakage @ 50Pa0.6 ACH/hour
- PER demand52.7kWh/m2/year
Passive House Database -TBA
Construction Details Average Values
- U-value External Walls0.36 W/(m2K)(R2.77)
- 90 and 140mm timber framed walls with R2.5/R3.2 Mammoth batts, Intello air control layer, 45mm service cavity with R1.3 Mammoth batts, plasterboard.
- U-value Floor0.21W/(m2K)(R4.72)
- Suspended timber floor with two layers R2.9 Mammoth batts, ply windwash protection.
- U-value Roof 0.18W/(m2K)(R5.44)
- Skillion & timber truss roofs with two layers R2.9 Mammoth batts, Intello air control layer uninsulated ceiling service cavity, plasterboard.
- U-value Glass1.12 W/(m2K)(R0.89)
- Eco Windows double - PLANICLEAR 4/16/4Ar 90
- U-Windows1.4 W/(m2K)(R0.7)
- Eco windows PVC83
- Ventilation Efficiency90%
- Wolf CWL-2-325