Premier Homes – Genesis Bayswater AU

   House Profile

Project Team

Architecture & Passive House Design  Green Point Design
Builder G-LUX Builders - gluxbuilders.com.au

Certifier Sustainable Engineering Ltd – sustainableengineering.co.nz

Passive House Metrics

  • Heating Demand13.1 kWh/m2/year
  • Heating Load10.6W/m
  • TFA87.3m2
  • Form Factor3.8
  • Air leakage @ 50Pa0.4 ACH/hour
  • PER demand38.4kWh/m2/year

Passive House Database - TBA

Construction Details Average Values

  • U-value External Walls 0.19 W/(m2K)(R5.2)
  •  90mm Insulated Timber Framed Wall with 50mm PIR on interior
  • U-value Floor0.18W/(m2K)(R5.5)
  • 190mm Insulated I-Joist floor with 40mm PIR on interior
  • U-value Roof 0.11W/(m2K)(R8.8)
  • 300mm Insulated I-Joist roof with 40mm PIR on interior
  • U-value Glass0.75 W/(m2K)(R1.3)
  •  Viridian 4/12 Argon/4/12 Argon/4
  • U-Windows1.2W/(m2K)(R0.9)
  • Kommerling
  • Ventilation Efficiency 81%
  • Zehnder ComfoAir 180